We custom-designed this high-pressure radial induced draft fan for a scrubber application, with alloy 2205 airstream construction, custom purge air shaft seals, pie-split housing, and an integral inlet box. Configured as a center-hung Arrangement 7 fan, a flexible coupling is used to connect the fan shaft to the motor shaft, and the entire fan assembly is mounted on a unitary base. The application required a severe duty motor rated for use with a Variable Frequency Drive (VFD).

We provided these custom high-pressure SCR blowers (one primary with an identical redundant/backup blower) for this mission-critical Selective Catalytic Reduction (SCR) application. Designed for high-temperature operation at 800 degrees max design temperature with a tight 15-degree min/max rate of temperature change. The blowers have 15 HP IEEE841-rated premium-efficiency, severe-duty motors to meet the high standard required for operation in the petroleum and chemical industry.

We built this induced draft radial tipped fan for a wet scrubber with a saturated airstream. This application called for an abrasion-resistant wheel and housing with scroll liners and a flexible direct coupled drive. The heavy-duty self-cleaning Radial Tipped Fan delivers process control, stability, and high static efficiency while resisting material buildup on the wheel and impeller.